Insulating Steel Window Supports

Steel Window Supports Needing insulated Foil Faced Aerogel Stuck directly to the steel posts. VCL Flanges Glued to Opposite foil to make air and vapour tight.All Junctions Insulated and Taped. VCL Flanges Glued to Opposite foil to make air and vapour tight. Window Supports Cambourn Park (59)

 

Foil faced Aerogel Blanket being fixed to the steel window supports before the windows were installed during a deep retrofit in Belfast Northern Ireland. 10mm Aerogel Blanked it sufficient to eliminate the risk of condensation / cold bridging  at this area.

joepassmore